The relationship of muscle oxygen saturation analyzer with other monitoring and quantification tools in a maximal incremental treadmill test

Introduction: The study aims to explore whether NIRS derived data can be used to identify the second ventilatory threshold (VT2) during a maximal incremental treadmill test in non-professional runners and to determine if there is a correlation between SmO2 and other valid and reliable exercise performance assessment measures or parameters for maximal incremental test, such as lactate concentration (LT), RPE, HR, and running power (W). Methods: 24 participants were recruited for the study (5 women and 19 men). The devices used consisted of the following: i) a muscle oxygen saturation analyzer placed on the vastus lateralis of the right leg, ii) the Stryd power meter for running, iii) the Polar H7 heart rate band; and iv) the lactate analyzer. In addition, a subjective perceived exertion scale (RPE 1-10) was used. All of the previously mentioned devices were used in a maximal incremental treadmill test, which began at a speed of 8 km/h with a 1% slope and a speed increase of 1.2 km/h every 3 min. This was followed by a 30-s break to collect the lactate data between each 3-min stage. Spearman correlation was carried out and the level of significance was set at p < 0.05. Results: The VT2 was observed at 87,41 ± 6,47% of the maximal aerobic speed (MAS) of each participant. No relationship between lactate data and SmO2 values (p = 0.076; r = -0.156) at the VT2 were found. No significant correlations were found between the SmO2 variables and the other variables (p > 0.05), but a high level of significance and strong correlations were found between all the following variables: power data (W), heart rate (HR), lactate concentration (LT) and RPE (p < 0.05; r > 0.5). Discussion: SmO2 data alone were not enough to determine the VT2, and there were no significant correlations between SmO2 and the other studied variables during the maximal incremental treadmill test. Only 8 subjects had a breakpoint at the VT2 determined by lactate data. Conclusion: The NIRS tool, Humon Hex, does not seem to be useful in determining VT2 and it does not correlate with the other variables in a maximal incremental treadmill test. Highlights - Humon Hex is a small, portable and non-invasive device for measuring local SmO2 in a muscle and it provides instant feedback. - Humon Hex is not a good device for identifying VT2 during a maximal incremental treadmill test. - The Humon Hex monitor showed no correlation between SmO2 and the other variables such as lactate, heart rate, RPE, and W during a maximal incremental treadmill test.
© Copyright 2023 Frontiers in Physiology. EPFL. Kaikki oikeudet pidätetään.

Aiheet: aerobinen-anaerobinen kynnys suoritusdiagnostiikka hapenottokyky lihas lihasfysiologia suorituskyky kestävyysjuoksu juoksu ventilaatiokynnys syke laktaatti anturi mittaus- ja tietojärjestelmä
Aihealueet: valmennusoppi biologiset ja lääketieteelliset tieteet tekniset ja luonnontieteet
Tagging: Nahinfrarotspektroskopie Sauerstoffsättigung
DOI: 10.3389/fphys.2023.1155037
Julkaisussa: Frontiers in Physiology
Julkaistu: 2023
Vuosikerta: 14
Sivuja: 1155037
Julkaisutyypit: artikkeli
Kieli: englanti (kieli)
Taso: kehittynyt